Closed
[Bug-Report|缺陷反馈]: 设备瞬态错误(F71008 MAP_REG_ADDR_FAILED / AICPU 507018)排障流程缺少"先重试"指引,扫卡换设备会放大问题 #2824
liuxiaoxiao11Add on Jul 30Closed at Aug 31
Jul 30 Assign quadrate as responsible person
Aug 25 Associated pull request
anyangle
Aug 27 Comments:
Aug 27 Comments:
感谢指出问题,当前文档已重新修改排障流程


Aug 31 changed custom state from 进行中 to 已解决
Aug 31 Close issue
Aug 31 Added label: resolved
trouble_shooting/machine.md:58-75的 F71008 处理流程无"瞬态优先重试",用户第一反应是换空闲设备npu-smi info -t usages -i 13报Invalid card id.— 本机 8 card (0-7) 每卡 2 chip,TILE_FWK_DEVICE_ID=13是 chip id,需用-i 6 -c 1。文档缺 card id vs chip id 拓扑说明Environment / 环境信息 (Mandatory / 必填)
Steps to reproduce the issue / 重现步骤 (Mandatory / 必填)
source /home/operation/Ascend/cann-9.1.0/bin/setenv.bash export PTO_TILE_LIB_CODE_PATH=/home/operation/Ascend/cann-9.1.0/aarch64-linux cd benchmark_runs/fracture-points/i-13 bash repro_f71008.sh 2>&1 | tee run.log复现代码:
benchmark_runs/fracture-points/i-13/可调参数:
REPRO_DEV(默认 13)、CTRL_DEV(默认 15)、NWORKERS(默认 3)、ROUNDS(默认 5)Describe the expected behavior / 预期结果 (Mandatory / 必填)
runtime/框架层:对 F71008 / 507018 做有限次自动重试
文档(高优先级):排障流程改为:
文档:machine 文档补 507018 瞬态条目
Related log / screenshot / 日志 / 截图 (Mandatory / 必填)
重试结果:
历史证据:
Task_0724/.../ds_v32_mla_prolog/.../root_full.md:43007-43009(3 连发 F71008)、tune_out_0725/logs/ds_v32_mla_prolog/optimizer_agent.log:888-891(5 连发后重试即过)Special notes for this issue/备注 (Optional / 选填)
machine.md §9修订(排障流程重排序)+machine.md §2注(507018 瞬态)