hisysevent (for System Applications Only)
hisysevent is a built-in tool that helps you subscribe to real-time system events and query historical system events.
Environment Requirements
-
The environment for OpenHarmony Device Connector (hdc) has been set up. For details, see Environment Setup.
-
The devices are properly connected and hdc shell is executed.
-
The hisysevent command is executed on the device to call related capabilities.
Subscribing to Real-Time System Events
-
Run the hisysevent -r command to subscribe to system events.

-
To specify the type of system event to subscribe to, use the -g option.
Note: With the -g option, four event types are available: FAULT, STATISTIC, SECURITY, and BEHAVIOR.
If no event type is specified, hisysevent subscribes to all types of system events.
Example: Subscribe to system events of the FAULT type.

-
To subscribe to system events by event domain and event name, use the -o, -n, and -c options. -o specifies the event domain, -n specifies the event name, and -c specifies the rule for matching the specified event domain and name.
NOTE With the -c option, the following matching rules are available: WHOLE_WORD, PREFIX, and REGULAR.
If no matching rule is specified, the WHOLE_WORD matching rule is used by default.
Example 1: Subscribe to the system event that matches the domain of AAFWK and event name of CONNECT_SERVICE.

Example 2: Subscribe to system events that match the domain prefix of AAF and event name prefix of CONNECT.

Example 3: Subscribe to system events whose domain matches the AA* regular expression and whose event name matches the CONNE* regular expression.

-
To subscribe to system events by event tag, use the -t and -c options. -t specifies the event tag, and -c specifies the rule for matching the event tag.
Example 1: Subscribe to system events whose tag is ability.

Example 2: Subscribe to system events whose tag prefix is abili.

Example 3: Subscribe to system events whose tag matches the abi* regular expression.

Querying Historical System Events
-
Run the hisysevent -l command to query system events that are stored.

-
To specify the type of system event to query, use the -g option.
NOTE With the -g option, four event types are available: FAULT, STATISTIC, SECURITY, and BEHAVIOR.
If no event type is specified, hisysevent queries all types of system events.
Example: Query system events of the SECURITY type.

-
To query historical system events within the specified period of time, use the -s and -e options to specify raw timestamps. -s specifies the start timestamp, and -e the end timestamp.
NOTE The raw timestamps are of millisecond precision.
Example: Query all system events reported between 1708604541551 and 1708604558551.

-
You can use the -S and -E options to specify formatted start and end timestamps, respectively.
NOTE The timestamp format is YYYY-MM-DD hh:mm:ss.
Example: Query all system events reported between 2024-02-22 20:22:21 and 2024-02-22 20:22:38.

-
To query system events by event domain and event name, use the -o, -n, and -c options. -o specifies the event domain, -n specifies the event name, and -c specifies the rule for matching the specified event domain and name.
NOTE The -c option for querying historical system events must be WHOLE_WORD.
If no matching rule is specified, the WHOLE_WORD matching rule is used by default.
Example: Query the system event that matches the domain of AAFWK and event name of CONNECT_SERVICE.

-
You can use the -m option to set the maximum number of historical events that can be queried.
NOTE If -m is not specified, a maximum of 10,000 system events are queried by default.


Checking System Event Validity
To enable system event validity check, use the -v option.
If system event validity check is enabled, invalid content contained in system events will be highlighted in red.
NOTE
Invalid content is defined as follows:
- Custom parameter key that is not configured.
- Type mismatch.
Example: For the system event named INTERACTION_APP_JANK of the ACE domain, the system event configuration does not contain the custom parameters DURITION and DISPLAY_ANIMATOR. If these parameters are contained in the event saved, they will be highlighted in red when system event validity check is enabled.