powermgr_thermal_manager:基于设备热管理的温度控制服务项目

暂无描述

Branch249Tags41
FilesLast commitLast update
3 years ago
1 year ago
4 years ago
1 year ago
1 year ago
2 years ago
1 year ago
1 year ago
1 year ago
4 years ago
4 years ago
4 years ago
2 years ago
3 years ago
1 year ago
1 year ago
3 years ago

Thermal Manager

Introduction

The Thermal Manager module provides the device temperature management and control capabilities to ensure the thermal safety and experience of the entire system.

Figure 1 Architecture of the Thermal Manager module

Key components of the Thermal Manager module:

  1. Thermal Manager: provides temperature query and callback APIs for applications and other subsystems.
  2. Thermal Service: implements core temperature control functions, such as temperature detection, temperature level arbitration, and action delivery, according to the configuration file.
  3. Thermal HDI: implements temperature driver information reporting and driver instruction delivery according to the configuration file.
  4. Thermal Protector: implements simplified temperature control in the non-running state according to the configuration file.

Directory Structure

/base/powermgr/thermal_manager
├── application                  # Native application
│   ├── init                     # Init configuration
│   └── protector                # Thermal Protector code
├── figures                      # Architecture
├── frameworks                   # Framework layer
│   ├── napi                     # NAPI layer
│   └── native                   # Native layer
├── interface                    # API layer
│   └── inner_api                # Internal APIs
├── sa_profile                   # SA profile
├── services                     # Thermal Service code
│   ├── native                   # Native layer
│   └── zidl                     # Zidl layer
├── test                         # Test code
│   ├── fuzztest                 # Fuzz test
│   ├── unittest                 # Unit test
│   ├── systemtest               # System test
│   └── utils                    # Test tools
└── utils                        # Utilities

Configuration Description

thermal_service_config.xml Configuration example:

<?xml version="1.0" encoding="UTF-8"?>
<thermal version="0.99" product="ipx">
    <base>
        <item tag="temperature_query_enum" value="soc,battery,shell,ambient"/>
    </base>
    <level>
        <sensor_cluster name="warm_base" sensor="shell">
            <item level="1" threshold="35000" threshold_clr="33000"/>
            <item level="2" threshold="37000" threshold_clr="35000"/>
            <item level="3" threshold="40000" threshold_clr="38000"/>
        </sensor_cluster>
        <sensor_cluster name="warm_safe" sensor="battery,pa">
            <item level="1" threshold="48000,60000" threshold_clr="45000,55000"/>
        </sensor_cluster>
    </level>
    <state>
        <item name="screen"/>
        <item name="charge"/>
    </state>
    <action>
        <item name="cpu"/>
        <item name="current"/>
        <item name="shut_down" param="100"/>
        <item name="thermal_level" strict="1"/>
    </action>
    <policy>
        <config name="warm_base" level="1">
            <cpu screen="1">2800000</cpu>
            <cpu screen="0">2400000</cpu>
            <current charge="1">1500</current>
            <thermal_level>3</thermal_level>
        </config>
        <config name="warm_base" level="2">
            <cpu screen="1">2200000</cpu>
            <cpu screen="0">1800000</cpu>
            <current charge="1">1200</current>
            <thermal_level>4</thermal_level>
        </config>
        <config name="warm_base" level="3">
            <cpu screen="1">1600000</cpu>
            <cpu screen="0">1200000</cpu>
            <current charge="1">1000</current>
            <thermal_level>5</thermal_level>
        </config>
        <config name="warm_safe" level="1">
            <shut_down>1</shut_down>
        </config>
    </policy>
</thermal>
thermal                          # Root directory. Wherein, version indicates the version number, and product indicates the product name.
├── base                         # base directory, used to configure basic parameters.
│   └── item                     # item directory. Wherein, tag indicates the configuration tag, and value indicates the configuration value.
├── level                        # level directory, used to store the temperature level information.
│   └── sensor_cluster           # sensor_cluster directory, used to configure a cluster of sensors. Wherein, name indicates the cluster name, and sensor indicates the sensor name.
│       └── item                 # item directory, used to configure the temperature level information. Wherein, level indicates the temperature level, threshold indicates the triggering temperature, and xxx_clr indicates the setback temperature.
├── state                        # state directory, used to configure the state machine. Wherein, name indicates the name of the state machine.
├── action                       # action directory, used to configure actions. Wherein, name indicates the name of the action, param indicates the action parameter, and strict indicates the arbitration scheme.
└── policy                       # policy directory, used to configure the policy for the corresponding temperature level.
    └── config                   # config directory, used to configure the action for the corresponding temperature level. Wherein, name is that of sensor_cluster, and the level is that of the item in sensor_cluster.
        └── <action_name>        # action name corresponding to the action value. The state condition and its value can be configured in this attribute.

Repositories Involved

Power Management Subsystem

powermgr_power_manager

powermgr_display_manager

powermgr_battery_manager

powermgr_thermal_manager

powermgr_battery_statistics