.. _ex-contralateral-referencing:
=======================================
Using contralateral referencing for EEG
=======================================
Instead of using a single reference electrode for all channels, some
researchers reference the EEG electrodes in each hemisphere to an electrode in
the contralateral hemisphere (often an electrode over the mastoid bone; this is
common in sleep research for example). Here we demonstrate how to set a
contralateral EEG reference.
"""
import mne
ssvep_folder = mne.datasets.ssvep.data_path()
ssvep_data_raw_path = (
ssvep_folder / "sub-02" / "ses-01" / "eeg" / "sub-02_ses-01_task-ssvep_eeg.vhdr"
)
raw = mne.io.read_raw(ssvep_data_raw_path, preload=True)
_ = raw.set_montage("easycap-M1")
raw.rename_channels({"TP9": "M1", "TP10": "M2"})
ch_names = mne.channels.make_1020_channel_selections(raw.info, return_ch_names=True)
ch_names["Left"].remove("M1")
ch_names["Right"].remove("M2")
mastoids = ["M1", "M2"]
rereferenced_midline_chs = (
raw.copy()
.pick(mastoids + ch_names["Midline"])
.set_eeg_reference(mastoids)
.drop_channels(mastoids)
)
for ref, hemi in dict(M2=ch_names["Left"], M1=ch_names["Right"]).items():
mne.set_bipolar_reference(raw, anode=hemi, cathode=[ref] * len(hemi), copy=False)
raw.rename_channels(lambda ch_name: ch_name.split("-")[0])
_ = raw.drop_channels(ch_names["Midline"]).add_channels([rereferenced_midline_chs])
fig = raw.plot_sensors(show_names=True, sphere="eeglab")